Parceiro de desenvolvimento de tecidos para moda feminina — MOQ à medida de 300 m, stock pronto a partir de um rolo, para marcas, fábricas e grossistas.

Wool Coating Shows Light-and-Dark Bars After Steam Press: Weft-Density Map, Barre Method, Reject Rule

D
Delia Equipe Editorial da Fursone
Published on Nov 19, 2026
Leitura de 8 min

A light-and-dark bar across a wool coating after the first steam press is a weft barre defect the purchase order must catch with a weft-density map, a named barre method, and a reject rule, not a visual surprise after cutting starts. Freeze intake until a full-width density map, a steam-press barre record, and a written disposition sit in the roll file. Generic replies often ask for an average pick count only. A 2026 coating order still needs both a numerical map and a post-press visual barre check before roll acceptance. Average picks alone can miss alternating high and low bands on a full-width coating.

Why Do Light-and-Dark Bars Appear After the First Steam Press?

A weft barre is a light-and-dark band running selvedge to selvedge, often hidden until the first steam press relaxes the cloth and makes pick-density or shade differences visible. First, look for a filling bar caused by pick-density variation, weft-count drift, or tension change in the weft package. Second, log bar width, repeat distance, and contrast under the agreed viewing conditions. A short regular repeat often points to weft-insertion timing, while a long irregular period often points to yarn-count drift. Finally, do not treat an average pick count as proof the roll is clean. According to ASTM D3775-17(2023), pick count belongs on a conditioned full-width laboratory sample, not a single opportunistic inch. In 2026 intake, 100% of first-press barre complaints should be filed against both a density map and a visual barre record. For example, alternating high and low bands can still average close to the approved standard. Residual movement after pressing is a related gate in residual shrinkage after the first steam press.

Which Weft-Density Map Belongs on the Purchase Order?

A weft-density map is a full-width record of picks at written stations, not a single average typed on a mill ticket. First, require counts after conditioning under ISO 139, because moisture can shift pick spacing. Second, name ISO 7211-2:2024 Method C, the traversing thread counter, or ASTM D3775-17(2023) for routine mapping, and keep Method A for disputes. Finally, write a width and length grid with five transverse stations in the ASTM D3775 style, repeats at the beginning, middle, and end of the roll, and a named selvedge exclusion. According to ISO 7211-2:2024, Method C is suitable for woven fabrics, and Method A has precedence when parties dispute a count. In a 2026 roll file, 100 percent of maps should show the method, the conditioning atmosphere, and the station grid. In practice, do not accept one 1-inch count on irregular coating; count over at least 100 weft threads, or the ISO 7211-2 minimum distance. A mill such as Fursone should file the map under the same Art Rev.

What Belongs in the Weft-Density and Barre PO Table?

A weft-density and barre table is a one-page annex listing the map grid, the count method, the steam-press barre check, and the reject rule, not a slogan about even weaving. First, paste the table into the purchase order before the beam is started. Second, require mill stamps and the map file against each row before dispatch. Finally, block garment-factory cutting until every row has a dated pass. According to ASTM D3775-17(2023), construction claims should rest on a named count method. In a 2026 annex, 100% of rows should name evidence, not a verbal assurance. For example, keep colourway, Art Rev, and method ID in the header.

Control Evidence before acceptance Fail if
Weft-density map Full-width grid after ISO 139 conditioning Average only, or one inch count
Count method ISO 7211-2:2024 Method C or ASTM D3775-17(2023) Unnamed mill count
Dispute method ISO 7211-2 Method A, independent laboratory Method switched after a fail
Steam-press barre check Full-width press, agreed conditions, two inspectors Four-point total only
Reject rule Visible continuous or repeating widthwise barre, or map outside written bands Verbal commercially acceptable claim.

How Should Weft Counts Be Taken Across Width and Length?

A proper weft count plan is a written grid of transverse and longitudinal stations on conditioned cloth, not a handful of convenient spots near one selvedge. First, condition the cloth in the ISO 139 standard atmosphere of 20 degrees Celsius and 65% relative humidity before any official count. Second, take five transverse readings in the ASTM D3775 manner, and repeat the set at the beginning, middle, and end of the roll, staying outside the named selvedge margin. Finally, record adjacent-station differences as well as the roll average, because banding can hide inside a passing mean. According to the ASTM D3775-17(2023) pick-count method, five counts across a full-width laboratory sample are the routine basis, not a single opportunistic inch. In 2026 mapping, 100 percent of official stations should be listed on the grid before weaving starts. For example, measure 2 times at a disputed station, then send the dispute path to ISO 7211-2 Method A.

Wool coating and boucle tweed cloth prepared for full-width weft-density mapping and steam-press barre inspection

Which Barre Inspection Method Should Follow the Steam Press?

A post-press barre inspection is a full-width visual check under agreed light and angles after the named steam-press condition, not a glance at a folded roll. First, lay a full-width length flat and view the cloth at agreed angles, including 30, 45, and 90 degrees, under D65. Second, add a backlight or trans-illumination pass, because density bands often show more clearly when light passes through the cloth. Finally, log bar width, spacing, and contrast on a written scale such as an AATCC or ASTM contrast grade. According to ASTM D5430, the Four-Point System can grade fabric defects, yet a four-point total alone can dilute a continuous widthwise bar across a long roll. In a 2026 inspection file, 100% of barre checks should follow the actual steam-press condition named on the purchase order. For example, two inspectors should confirm a visible continuous or repeating bar before a roll is released. In practice, an Atlas Streak Analyzer may be named for disputes if both parties agree.

When Should a Visible Barre Reject the Roll?

A barre reject rule is a written fail condition for a visible continuous or repeating widthwise bar after the agreed steam press, plus any map result outside the written bands, not a universal ISO percentage. First, treat a confirmed visible bar as a critical defect and a hold, even when the roll-average pick count sits inside the band. Second, write any density bands as contract controls against the approved standard roll; suggested figures such as a 2 percent or 3 percent average band are not ISO reject limits. Finally, send disputes to an independent laboratory using ISO 7211-2 Method A, not a fresh mill method chosen after the fail. According to ISO 7211-2:2024, Method A has precedence in a count dispute. In 2026 acceptance, 100 percent of rolls with a confirmed post-press barre should be held, not cut. For example, a four-point passing total does not override a visible post-press bar. Selvedge-to-selvedge shade should also be checked against the sealed retain used for half-width wool coating shade approval.

What Written Hold Should Purchasing Send Before Accepting the Roll?

A written hold is a dated intake instruction stopping cut-and-sew until the map, the post-press barre record, and a disposition are on file, not a polite remark in a chat thread. First, name the roll, Art Rev, colourway, and the missing evidence in the hold note. Second, require the mill to submit the weft-density map and the steam-press barre record under the methods already written on the purchase order. Finally, allow cutting only after a dated pass, or after a written reject and replacement plan. According to IWTO method-based trading practice, wool claims should rest on agreed methods rather than informal mill descriptions. In a 2026 hold file, 100% of stopped rolls should stay uncut until the annex rows are complete. For example, purchasing should refuse a verbal “still commercially acceptable” release. In practice, later rolls should inherit the same map and reject rule, not an average-only ticket.

What Must the Hold Note Name Before Cutting Starts?

A hold-note packet is a dated list of roll identity, missing map or barre evidence, and the cut-stop rule, not a vague quality complaint. First, record roll number, Art Rev, colourway, piece length, and the steam-press condition already named on the purchase order. Second, attach the failed or missing weft-density map and the post-press inspection sheet, including inspector names and D65 or backlight conditions. Finally, state in writing 1. no cutting, 2. no blending with clean rolls, and 3. no relabel as first quality, until a dated pass or reject is filed. According to IWTO commercial testing culture, a 2026 claim file should be auditable by method, not by memory. Keep 100 percent of hold notes in the same lot folder as the sealed retain. For example, a mill reply without station-level counts is not a complete map. In practice, two companies on the order, buyer and mill, should sign the same disposition line.

What Should the Next Purchase Order Repeat?

A repeatable barre clause is a standing purchase-order text copying the map grid, the named count methods, the steam-press barre check, and the reject rule onto the next colourway or repeat, not a one-roll email. First, copy the ISO 139 conditioning requirement and the ISO 7211-2:2024 or ASTM D3775-17(2023) method names into the next annex. Second, keep the written density bands and the visible-bar reject rule unchanged unless both parties sign a new standard roll. Finally, require the same two-inspector post-press check before acceptance. According to ASTM D3775-17(2023), pick-count work should stay method-based from roll to roll. In 2026 repeat orders, 100% of new purchase orders should carry the same barre annex. For example, an average pick ticket alone should remain a fail. In practice, a short regular bar still points to the weft path, and a long irregular bar still points to yarn-count drift, so both records stay mandatory.