A residual pH failure after a mothproof finish is an incoming-test problem the finish appendix must lock with a named method, a governing limit, and a re-finish rule, not a dispute after coats are already cut. Freeze cutting until the method, the written limit, and a same-method re-test or reject sit in the lot file. Generic replies often say “keep fabric pH neutral” and stop. A 2026 mothproofed coating still needs the garment-factory incoming method to govern disposition. Lock the extraction detail and the one-correction rule before the mothproof bath is set. A mill outgoing ticket alone is not enough when the factory test fails, and a pre-finish prep check is not a substitute for residual pH on the finished lot.
Why Does a Mothproof Finish Fail a Garment-Factory pH Test?
A residual pH fail after mothproofing is a wet-process leftover of un-rinsed alkali, unreacted catalyst, or a drifted finishing bath, not a mystery of the mothproof agent alone. First, treat the incoming result on the mothproofed lot as the release fact, not a greige or pre-finish prep check. Second, look for inadequate washing after alkaline dyeing or finishing, because some mothproof agents, such as permethrin, can decompose under high dye-bath pH. Finally, do not blend, ship, or cut a failed lot while the appendix is silent. According to AATCC TM81, pH of the water extract is used to judge washing and neutralization of wet-processed textiles, and the method does not itself quantify total alkali. In 2026 intake, 100% of mothproofed lots should arrive with a method-named pH report matching the factory test. For example, oil or mothball odour in the bale, covered in oil and mothball smell in the bale, is a separate hold, not a substitute for residual pH.
Which pH Method Should the Finish Appendix Name?
A finish-appendix pH method is a single named procedure, extraction solution, and reporting rule, not a generic line saying “fabric pH.” First, name AATCC TM81, also called AATCC 81, with hot-water extraction, a calibrated glass-electrode meter, and a report to 0.1 pH, or name ISO 3071:2020, not both as if the two results were interchangeable. Second, write specimen preparation and the incoming sampling plan in the same annex. Finally, forbid a method switch after a fail, including any attempt to adjust a reported pH by changing the extraction solution. According to ISO 3071:2020, the aqueous extract uses 0.1 mol/L potassium chloride, a procedure published on the BSI page for textile aqueous-extract pH. In a 2026 appendix, 100 percent of pH clauses should name one governing method for factory intake. For example, AATCC 144 alkalinity or ISO 4045, used mainly for leather, is the wrong citation for the incoming test. In practice, a mill such as Fursone should run the same named method at intake.
Why Are AATCC TM81 and ISO 3071 Not Interchangeable?
A method mismatch is a difference in extraction chemistry and procedure between AATCC TM81 and ISO 3071:2020, not a rounding error on the same extract. First, AATCC TM81 uses a water extract from wet-processed textiles, while ISO 3071:2020 uses a potassium chloride extract at 0.1 mol/L. Second, a pass under one method can still fail the other, so the appendix must pick the factory incoming method as the only release method. Finally, keep any extra alkalinity test as a root-cause tool, not a substitute for residual pH. According to AATCC TM81-2022, pH helps judge washing and neutralization, yet the textile pH method does not quantify total alkali present. In 2026 disputes, 100% of arbitration samples should be tested by the same incoming method already written in the appendix. For example, a mill water-extract pass cannot override a factory ISO 3071 fail if ISO 3071:2020 is the named method. In practice, ties and re-tests should follow the factory method, not a third method chosen after the fail.
Which pH Limit Governs Incoming Acceptance?
A governing pH limit is the factory incoming band written in the finish appendix, together with any destination-market legal ceiling the order must meet, not a number borrowed from a mill ticket. First, write the factory incoming range in the appendix before finishing starts. Second, if the destination market applies GB 18401, lock the published legal ceiling for the garment category and never write a wider band. Finally, if the brand contract is narrower than the legal ceiling, the narrower contract band governs intake. According to GB 18401-2010, published pH bands are 4.0–7.5 for Category A infant goods, 4.0–8.5 for Category B skin-contact goods, and 4.0–9.0 for Category C goods without direct skin contact. In a 2026 appendix, 100 percent of limits should state which regime governs. For example, some contracts write a narrower 5.5–7.5 or 5.0–7.0 band; such figures are contract controls, not ISO 3071 product limits. ISO 3071:2020 is a method, not a ready-made accept band.
What Belongs in the Finish-Appendix pH Table?
A finish-appendix pH table is a one-page annex listing the named method, extraction detail, governing limit, hold rule, and re-finish rule, not a verbal slogan. First, paste the table into the finish appendix before the mothproof bath is set. Second, require mill stamps and a same-method report against each row before dispatch. Finally, block factory cutting until every row has a dated pass. According to ISO 3071:2020, pH work should cite the aqueous-extract procedure actually used. In a 2026 annex, 100% of rows should name evidence, not a verbal assurance. For example, keep style, Art Rev, and method ID in the header.
| Control | Evidence in the finish appendix | Fail if |
|---|---|---|
| Named pH method | AATCC TM81 or ISO 3071:2020, one governing method | Fabric pH with no method |
| Extraction detail | Water extract or 0.1 mol/L KCl as the named method requires | Method changed after a fail |
| Governing limit | Factory incoming band, plus GB 18401 ceiling where required | Mill outgoing result only |
| Hold rule | Lot held; no blend, ship, or cut | Re-ship without correction |
| Re-finish rule | Approved correction, same-method re-test, mothproof check | Second fail without written disposition. |
How Should a Failed Lot Be Re-Finished and Re-Tested?
A re-finish rule is a hold, an approved corrective wash or neutralization, a same-method re-test, and a mothproof-performance check, not a re-ship of the same lot with a new ticket. First, place the failed lot on hold and notify the mill with the factory incoming result. Second, allow one approved correction, such as a mild acid neutralization and thorough rinse, or a full strip, neutralize, and re-apply of the mothproof finish under controlled bath pH, provided mothproof performance is re-checked. Finally, release only when two independently sampled specimens pass the same incoming method and mothproof, colour, handle, and dimensional checks remain acceptable. According to AATCC TM81, a 2026 re-test should use the identical incoming method, not mill self-certification. In practice, a second fail requires lot rejection or a written technical disposition signed by both parties. For example, 100 percent of corrected lots should travel with a new same-method report. Inadequate rinsing remains a common cause of a second pH fail.

Why Must the Factory Incoming Method Govern a Dispute?
A factory-method governance rule is a written statement giving the garment-factory incoming test, not the mill outgoing test, the power to dispose the lot when the two results disagree. First, name the incoming method, extraction, and sampling plan as the only arbitration path. Second, require retained samples from the same mothproofed lot for any re-test, under the same conditioning rules already used at intake. Finally, refuse a post-fail change to a “more convenient” extract. According to ISO 3071:2020 and AATCC TM81, each method has a defined extract, so mixing the two after a fail is not a valid tie-breaker. In 2026 quality files, 100% of disputes should stay on the appendix method. For example, a mill ISO 3071 pass cannot release a lot if the appendix named AATCC TM81 as the factory method. In practice, finishing pH control is also a process issue, as residual shrinkage work in residual shrinkage after the first steam press already shows: named methods beat informal mill descriptions.
What Written Hold Should Purchasing Send the Mill Today?
A written pH hold is a dated stop on cutting, blending, and shipment until a same-method pass or a signed reject is on file, not a chat remark about slightly high pH. First, name the lot, Art Rev, colourway, the incoming method, the result to 0.1 pH, and the governing limit already written in the appendix. Second, require the mill to hold the goods and to propose one approved correction without impairing mothproof performance. Finally, allow intake only after the factory repeats the identical method on independently sampled specimens. According to AATCC TM81, reporting to 0.1 pH keeps the hold note auditable. In a 2026 hold file, 100 percent of failed lots should stay uncut. For example, purchasing should refuse a verbal “re-finished, please accept” note without a new same-method report. In practice, two companies on the order, buyer and mill, should sign the same disposition line before any re-ship.
What Should the Next Purchase Order Repeat?
A repeatable pH clause is standing appendix text copying the named method, the governing limit, and the one-correction re-finish rule onto the next colourway, not a one-lot exception. First, copy AATCC TM81 or ISO 3071:2020, including extraction detail, into the next finish appendix. Second, keep the factory incoming band and any GB 18401 ceiling unchanged unless both parties sign a new limit. Finally, require the same hold, re-test, and mothproof-check path after any fail. According to ISO 3071:2020, method identity should stay stable from lot to lot. In 2026 repeat orders, 100% of new purchase orders should carry the same pH annex. For example, a pre-finish prep check is still not a substitute for residual pH on the mothproofed lot as received. In practice, later lots should not drift back to an unnamed “fabric pH” line on the next colourway.